<?xml version="1.0" encoding="UTF-8"?>
<crossref_result xmlns="http://www.crossref.org/qrschema/3.0" version="3.0" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.crossref.org/qrschema/3.0 http://www.crossref.org/schemas/crossref_query_output3.0.xsd">
  <query_result>
    <head>
      <doi_batch_id>none</doi_batch_id>
    </head>
    <body>
      <query status="resolved">
        <doi type="journal_article">10.31254/dentistry.2023.8206</doi>
        <crm-item name="publisher-name" type="string">BioMed Research Publishers</crm-item>
        <crm-item name="prefix-name" type="string">BioMed Research Publishers</crm-item>
        <crm-item name="member-id" type="number">16195</crm-item>
        <crm-item name="citation-id" type="number">155123112</crm-item>
        <crm-item name="journal-id" type="number">314763</crm-item>
        <crm-item name="deposit-timestamp" type="number">20231116192124950</crm-item>
        <crm-item name="owner-prefix" type="string">10.31254</crm-item>
        <crm-item name="last-update" type="date">2023-11-16T19:37:08Z</crm-item>
        <crm-item name="created" type="date">2023-11-16T19:21:25Z</crm-item>
        <crm-item name="citedby-count" type="number">0</crm-item>
        <doi_record>
          <crossref xmlns="http://www.crossref.org/xschema/1.1" xsi:schemaLocation="http://www.crossref.org/xschema/1.1 http://doi.crossref.org/schemas/unixref1.1.xsd">
            <journal>
              <journal_metadata>
                <full_title>International Journal of Dentistry Research</full_title>
                <abbrev_title>Int J Dentistry Res.</abbrev_title>
                <issn media_type="electronic">25813218</issn>
                <doi_data>
                  <doi>10.31254/dentistry</doi>
                  <resource>https://www.dentistryscience.com/</resource>
                </doi_data>
              </journal_metadata>
              <journal_issue>
                <publication_date media_type="online">
                  <month>8</month>
                  <day>30</day>
                  <year>2023</year>
                </publication_date>
                <journal_volume>
                  <volume>8</volume>
                </journal_volume>
                <issue>2</issue>
              </journal_issue>
              <journal_article publication_type="full_text">
                <titles>
                  <title>Comparative study on the efficacy of gingival retraction using Retraction cord and Expasyl paste in implant patients In-vivo study</title>
                </titles>
                <contributors>
                  <person_name sequence="first" contributor_role="author">
                    <given_name>Chitra</given_name>
                    <surname>Goyal</surname>
                  </person_name>
                  <person_name sequence="additional" contributor_role="author">
                    <given_name>Sunil</given_name>
                    <surname>Kumar Mv</surname>
                  </person_name>
                  <person_name sequence="additional" contributor_role="author">
                    <given_name>Alok</given_name>
                    <surname>Sharma</surname>
                  </person_name>
                  <person_name sequence="additional" contributor_role="author">
                    <given_name>Rahi</given_name>
                    <surname>Goyal</surname>
                  </person_name>
                  <person_name sequence="additional" contributor_role="author">
                    <given_name>Shirish</given_name>
                    <surname>Sharma</surname>
                  </person_name>
                </contributors>
                <jats:abstract xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1" xml:lang="en">
                  <jats:p>Introduction: The precise reproduction of the abutment (implant) provides clinician with crucial clinical information of the relative position and orientation of the implant to other implants, teeth and soft tissue that allow them to fabricate exact- fitting, bio-integrated restoration. For that it is necessary to expose, access &amp; isolate the implant region, especially when cement retained implant prosthesis are in consideration, where conventional crown and bridge impression and optical impression technique is used. Material and Method: Patient who accepted to participate were chosen for the study. Coincidentally all 15 patients were female. They were explained the purpose and methodology, agreed for periodic follow up at the interval of one month after placement of healing abutment and 7 days after using the retraction cord. Conclusion: The conclusions that were drawn from this study are: Both materials showed clinically and statistically significant amount of vertical soft tissue displacement. Among the both soft tissue displacement agents, non-impregnated retraction cord showed the more vertical soft tissue displacement than Expasyl Paste. But, the amount of retraction offered by this paste is limited with extremely subgingival margins. But the advantages with Expasyl paste over the retraction cord were its ease of application, painless, quick, and without agony to the patient.</jats:p>
                </jats:abstract>
                <publication_date media_type="online">
                  <month>8</month>
                  <day>30</day>
                  <year>2023</year>
                </publication_date>
                <pages>
                  <first_page>49</first_page>
                  <last_page>56</last_page>
                </pages>
                <crossmark>
                  <crossmark_version>1</crossmark_version>
                  <crossmark_policy>10.31254/biomed-crossmark-policy</crossmark_policy>
                  <crossmark_domains>
                    <crossmark_domain>
                      <domain>www.biomedresearch.org</domain>
                    </crossmark_domain>
                  </crossmark_domains>
                  <crossmark_domain_exclusive>false</crossmark_domain_exclusive>
                </crossmark>
                <doi_data>
                  <doi>10.31254/dentistry.2023.8206</doi>
                  <resource>https://www.dentistryscience.com/IJDR_202382_06.pdf</resource>
                </doi_data>
                <citation_list>
                  <citation key="ref0">
                    <unstructured_citation>1. Al-Ani A, Bennani V, Chandler NP, Lyons KM, Thomson WM. New Zealand dentists' use of gingival retraction techniques for fixed prosthodontics and implants. NZ Dent J. 2010 Sep 1;106(3):92-6.</unstructured_citation>
                  </citation>
                  <citation key="ref1">
                    <doi>10.14219/jada.archive.2008.0047</doi>
                    <unstructured_citation>2. Bennani V, Schwass D, Chandler N. Gingival retraction techniques for implants versus teeth: current status. The Journal of the American Dental Association. 2008 Oct 1;139(10):1354-63.</unstructured_citation>
                  </citation>
                  <citation key="ref2">
                    <journal_title>Brazilian Oral Research</journal_title>
                    <author>Chang</author>
                    <volume>25</volume>
                    <first_page>492</first_page>
                    <cYear>2011</cYear>
                    <doi>10.1590/S1806-83242011000600004</doi>
                    <article_title>Effect of a cordless retraction paste material on implant surfaces: an in vitro study</article_title>
                    <unstructured_citation>3. Chang YS, Bennani V, Tawse-Smith A, Girvan L. Effect of a cordless retraction paste material on implant surfaces: an in vitro study. Brazilian Oral Research. 2011;25:492-9.</unstructured_citation>
                  </citation>
                  <citation key="ref3">
                    <unstructured_citation>4. Kamath R, Sarandha DL, Baid GC. Advances in gingival retraction. International Journal of Clinical Dental Science. 2011;2(1).</unstructured_citation>
                  </citation>
                  <citation key="ref4">
                    <doi>10.1038/sj.bdj.4813947</doi>
                    <unstructured_citation>5. Handelsman M. Surgical guidelines for dental implant placement. British Dental Journal. 2006 Aug;201(3):139-52.</unstructured_citation>
                  </citation>
                  <citation key="ref5">
                    <doi>10.4103/0972-124X.115666</doi>
                    <unstructured_citation>6. Jyothi SG, Triveni MG, Mehta DS, Nandakumar K. Evaluation of single-tooth replacement by an immediate implant covered with connective tissue graft as a biologic barrier. Journal of Indian Society of Periodontology. 2013 May;17(3):354.</unstructured_citation>
                  </citation>
                  <citation key="ref6">
                    <unstructured_citation>7. Shillingburg HT, Hobo S, Whitsett LD, Jacobi R, Brackett SE. Fundamentals of fixed prosthodontics, Quintessence Pub. 2011.</unstructured_citation>
                  </citation>
                  <citation key="ref7">
                    <unstructured_citation>8. Expasyl Technique Tips &amp; Troubleshooting.ftp.endoco.com/link/KerrExpasylTechnicalinfo. Pdf:1-9</unstructured_citation>
                  </citation>
                  <citation key="ref8">
                    <journal_title>Journal of Clinical Periodontology</journal_title>
                    <author>Al Hamad</author>
                    <volume>35</volume>
                    <first_page>1053</first_page>
                    <cYear>2008</cYear>
                    <doi>10.1111/j.1600-051X.2008.01335.x</doi>
                    <article_title>A clinical study on the effects of cordless and conventional retraction techniques on the gingival and periodontal health</article_title>
                    <unstructured_citation>9. Al Hamad KQ, Azar WZ, Alwaeli HA and Said KN. A clinical study on the effects of cordless and conventional retraction techniques on the gingival and periodontal health.Journal of Clinical Periodontology 2008;35:1053-58.</unstructured_citation>
                  </citation>
                  <citation key="ref9">
                    <doi>10.4103/0972-124X.65436</doi>
                    <unstructured_citation>10. Phatale S, Marawar PP, Byakod G, Lagdive SB, Kalburge JV. Effect of retraction materials on gingival health: A histopathological study. Journal of Indian Society of Periodontology. 2010 Jan;14(1):35.</unstructured_citation>
                  </citation>
                  <citation key="ref10">
                    <doi>10.4103/2229-5194.85023</doi>
                    <unstructured_citation>11. Prasad KD, Hegde C, Agrawal G, Shetty M. Gingival displacement in prosthodontics: A critical review of existing methods. Journal of interdisciplinary dentistry. 2011 Jul 1;1(2):80-6.</unstructured_citation>
                  </citation>
                  <citation key="ref11">
                    <doi>10.1016/S0022-3913(12)60097-3</doi>
                    <unstructured_citation>12. Bennani V, Aarts JM, He LH. A comparison of pressure generated by cordless gingival displacement techniques. The Journal of Prosthetic Dentistry. 2012 Jun 1;107(6):388-92.</unstructured_citation>
                  </citation>
                  <citation key="ref12">
                    <doi>10.1007/s13191-012-0140-y</doi>
                    <unstructured_citation>13. Gupta A, Prithviraj DR, Gupta D, Shruti DP. Clinical evaluation of three new gingival retraction systems: A research report. The Journal of Indian Prosthodontic Society. 2013 Mar;13:36-42.</unstructured_citation>
                  </citation>
                  <citation key="ref13">
                    <unstructured_citation>14. Gupta R, Aggarwal R, Siddiqui Z. Comparison of various methods of gingival retraction on gingival and Periodontal health and marginal fit. Int J Oral Health Dent (IJOHD). 2016;2:243-7.</unstructured_citation>
                  </citation>
                  <citation key="ref14">
                    <unstructured_citation>15. Rao BD, Nayar S, Rajyalakshmi R, Rajmohan CS. Comparative evaluation of gingival displacement using Expasyl, Magic foam cord and Medicated retraction cord-An in-vivo study. Trends in Prosthodontics and Dental Implantology. 2012 Dec 15;3(1):8-11.</unstructured_citation>
                  </citation>
                </citation_list>
              </journal_article>
            </journal>
          </crossref>
        </doi_record>
      </query>
    </body>
  </query_result>
</crossref_result>